Prime 56B
Prime 56B | ||
---|---|---|
Chamber Volume | 56 Liter | 14.8 gal |
Chamber Size | Ø 380 x 522 mm | Ø 15.0 x 20.6 in |
Clean Water Reservoir Capacity | 8 Liter | 2.1 gal |
Waste Water Reservoir Capacity | 8 Liter | 2.1 gal |
Dimensions (W x H x D) | 719 x 536 x 728 mm | 28.3 x 21.1 x 28.7 in |
Net Weight | 105.5 kg |
232.6 lb |
Gross Weight | 108 kg |
238.1 lb |
Voltage / Frequency | 230 V / 50-60 Hz | |
Power / Current | 3,000 W / 13.1 A | |
Altitude | Under 3,000 m | |
Air Removal | Pre-Vacuum | |
Drying | Post-Vacuum | |
Recorder | Built-in 2.0 GB memory | |
Printer | Real-time Printer |
ISO 13485:2016 Quality Management System - Medical Devices
PED 2014/68/EU Pressure Equipment Directive
ASME BPVC Section VIII-1 Rules for Construction of Pressure Vessels
EN 13060 Small Steam Sterilizers
EN/IEC 61010-1 Safety Requirements for measurement control and laboratory use
EN/IEC 61010-2-040 Safety requirements for sterilizers used to treat medical materials
EN/IEC 61326-1 EMC
RoHS Restriction of Hazardous Substances Directive 2011/65/EU)
Tray Set
Square tray holder with a capacity of four perforated sieve trays, made of 304 stainless steel.
Tray dimensions (W x H x D):
280 x 38 x 409 mm
Wire-Mesh Basket
Sterilization basket, made of 304 stainless steel wire.
Container dimensions (W x H x D) :
295 x 215 x 380 mm
SteriProcess IoT Server
A web, smartphone and tablet application that allows you to monitor the status of autoclaves wherever you are and save a backup of the cycle history database on server for management analysis.
Wi-Fi Dongle
Support hot swapping, so that the Prime Series can receive wireless network signal.
RO Water Filter
Filter out dirt odor, chlorine and salt; extending life usage of the sterilizer and quality.
Quicker production & supply RO water.
Water Distiller
Water distiller turns water into steam to remove fluoride, arsenic, lead, viruses and other contaminants, protecting your sterilizer and instruments at a fraction of cost.
Barcode Scanner
Barcode for scanning user profiles or sterilization loads to record sterilization data.
Barcode Printer
Sterilization labels for continuous production, safely tag loads in a few simple steps.
Air Filter
Filtering effect of air particles under 0.3μm is over 99.99%.
Cham-mate Cleaner
Autoclave chamber & piping cleaner.
(10 bags/ paper box)
Printer Paper
Supplies, used to print sterilization data on printer.
Drain Filter
Filter the impurities in the sterilized waste water to avoid clogging the pipe.
According to the filter condition, it needs to be cleaned or renewed.
Prime 56B | ||
---|---|---|
Chamber Volume | 56 Liter | 14.8 gal |
Chamber Size | Ø 380 x 522 mm | Ø 15.0 x 20.6 in |
Clean Water Reservoir Capacity | 8 Liter | 2.1 gal |
Waste Water Reservoir Capacity | 8 Liter | 2.1 gal |
Dimensions (W x H x D) | 719 x 536 x 728 mm | 28.3 x 21.1 x 28.7 in |
Net Weight | 105.5 kg |
232.6 lb |
Gross Weight | 108 kg |
238.1 lb |
Voltage / Frequency | 230 V / 50-60 Hz | |
Power / Current | 3,000 W / 13.1 A | |
Altitude | Under 3,000 m | |
Air Removal | Pre-Vacuum | |
Drying | Post-Vacuum | |
Recorder | Built-in 2.0 GB memory | |
Printer | Real-time Printer |
ISO 13485:2016 Quality Management System - Medical Devices
PED 2014/68/EU Pressure Equipment Directive
ASME BPVC Section VIII-1 Rules for Construction of Pressure Vessels
EN 13060 Small Steam Sterilizers
EN/IEC 61010-1 Safety Requirements for measurement control and laboratory use
EN/IEC 61010-2-040 Safety requirements for sterilizers used to treat medical materials
EN/IEC 61326-1 EMC
RoHS Restriction of Hazardous Substances Directive 2011/65/EU)